Avalon-stoves Arbor PS Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Ferramentas Avalon-stoves Arbor PS. Avalon Stoves Arbor PS User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 42
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Arbor
Pellet Stove
Horizontal Or Vertical Vent
Freestanding Stove
Mobile Home Approved
Class A Chimney Retrofit
Hearth Stove into Existing
Masonry Chimney , Masonry
Fireplace, or Z.C. Fireplace
Tested and Listed by
Omni-Test Laboratories, Inc.
Beaverton, Oregon
Report # 028-S-77-2
ASTM E1509-2004
-- Please read this entire manual before installation and use of this pellet fuel-
burning room heater. Failure to follow these instructions could result in property
damage, bodily injury, or even death.
-- Contact local building or fire officials about restrictions and installation inspection
requirements in your area.
-- Save these instructions.
Installer: After installation give this manual to the home-owner and
explain operation of this stove.
$10.00 Copyright 2007, T.I. Part # 100-01191_000
4070806
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
Vista de página 0
1 2 3 4 5 6 ... 41 42

Resumo do Conteúdo

Página 1 - Pellet Stove

ArborPellet Stove• Horizontal Or Vertical Vent• Freestanding Stove• Mobile Home Approved• Class A Chimney Retrofit• Hearth Stove into ExistingMasonry

Página 2 - Introduction

10 Installation (For Qualified Installers Only)© Travis Industries 4070806 100-01191_000Pellet Vent Type• Must be 4" diameter Type "L"

Página 3 - Table of Contents 3

Installation (For Qualified Installers Only) 11© Travis Industries 4070806 100-01191_000Mobile Home Requirements• Outside air is required (used forco

Página 4 - Safety Precautions

12 Installation (For Qualified Installers Only)© Travis Industries 4070806 100-01191_000Alcove Installation RequirementsWhen the pellet stove is plac

Página 5 - Safety Precautions 5

Installation (For Qualified Installers Only) 13© Travis Industries 4070806 100-01191_000Thermostat Installation! Do not connect 120 VAC to the thermo

Página 6 - Specifications

14 Installation (For Qualified Installers Only)© Travis Industries 4070806 100-01191_000Installation Example: Direct "Through-the-wall" Ins

Página 7

Installation (For Qualified Installers Only) 15© Travis Industries 4070806 100-01191_000Installation Example: Interior Vertical InstallationFloor Pr

Página 8

16 Installation (For Qualified Installers Only)© Travis Industries 4070806 100-01191_000Installation Example: Class A Chimney RetrofitFloor Protectio

Página 9 - Venting the Pellet Stove

Installation (For Qualified Installers Only) 17© Travis Industries 4070806 100-01191_000Installation Example: Masonry Fireplace Hearth Stove“L” Vent

Página 10 - Silicone

18 Installation (For Qualified Installers Only)© Travis Industries 4070806 100-01191_000Installation Example: Zero-Clearance (Metal) Fireplace Hearth

Página 11 - Mobile Home Requirements

Installation (For Qualified Installers Only) 19© Travis Industries 4070806 100-01191_000Installation Example: Freestanding Masonry Chimney6” Min.Allo

Página 12 - Restrictor Adjustment

2 Introduction© Travis Industries 4070806 100-01191_000IntroductionWe welcome you as a new owner of an Arbor pellet heater. In purchasing an Arbor yo

Página 13 - Thermostat Installation

20 Operation© Travis Industries 4070806 100-01191_000Safety NoticeRead this entire manual (especially the "Safety Precautions" on pages 4 an

Página 14

Operation 21© Travis Industries 4070806 100-01191_000Loading PelletsLift the hopper lid to its vertical position. Pour pellets into the hopper until

Página 15 - 4070806 100-01191_000

22 Operation© Travis Industries 4070806 100-01191_000Manual ModeManual mode requires the user to turn theheater on and off manually.To StartPress the

Página 16

Operation 23© Travis Industries 4070806 100-01191_000Auto ModeAuto mode allows you to use a thermostat to control room temperature. The stove automat

Página 17

24 Operation© Travis Industries 4070806 100-01191_000Restrictor AdjustmentThe restrictor “fine tunes” your appliance, adjusting the amount of air flow

Página 18

Operation 25© Travis Industries 4070806 100-01191_000Start-Up SequenceThis stove utilizes a start-up sequence whenever the mode switch is changed or t

Página 19

26 Operation© Travis Industries 4070806 100-01191_000Using a Pellet/Corn Mix with This HeaterThis heater may burn a mixture of corn and wood pellets u

Página 20 - Operation

Maintenance 27© Travis Industries 4070806 100-01191_000Daily Maintenance (whenever using the stove)Inspect the BurnWhen burning on high, theflames sho

Página 21 - Operation 21

28 Maintenance© Travis Industries 4070806 100-01191_000Daily Maintenance (whenever using the stove) - ContinuedCheck Firepot forClinkersIf the flames

Página 22

Maintenance 29© Travis Industries 4070806 100-01191_000Daily Maintenance (whenever using the stove) - ContinuedDoor OpeningWARNING : Make sure the h

Página 23 - Operation 23

Table of Contents 3© Travis Industries 4070806 100-01191_000IntroductionIntroduction...2Important I

Página 24

30 Maintenance© Travis Industries 4070806 100-01191_000Bi-Weekly Maintenance (or every 10 bags of pellets)Flyash RemovalThis heater was designed to al

Página 25 - Operation 25

Maintenance 31© Travis Industries 4070806 100-01191_000Bi-Weekly Maintenance (or every 10 bags of pellets) - continuedClean the BafflesWARNING : Ma

Página 26

32 Maintenance© Travis Industries 4070806 100-01191_000Bi-Weekly Maintenance (or every 10 bags of pellets) - continuedSweep Ash Into AshpanWARNING :

Página 27 - Maintenance 27

Maintenance 33© Travis Industries 4070806 100-01191_000Bi-Weekly Maintenance (or every 10 bags of pellets) - continuedCheck Ashpan, Dispose if necessa

Página 28 - Maintenance

34 Maintenance© Travis Industries 4070806 100-01191_000Yearly Maintenance (or every two tons)The following section details extensive maintenance proce

Página 29 - Maintenance 29

Maintenance 35© Travis Industries 4070806 100-01191_000Yearly Maintenance (or every two tons) - continuedRemove the button plugs at the top of the fir

Página 30

36 Maintenance© Travis Industries 4070806 100-01191_000Yearly Maintenance (or every two tons) - continuedClean the Exhaust BlowerThe exhaust blower co

Página 31 - Maintenance 31

Maintenance 37© Travis Industries 4070806 100-01191_000Yearly Maintenance (or every two tons) - continuedClean the Convection BlowerRemove all dust an

Página 32

38 Maintenance© Travis Industries 4070806 100-01191_000Replacement PartsDoor Replacement Parts59810437261ID # Description Qty Part # ID # Description

Página 33 - Maintenance 33

Normal Operating Sounds 39© Travis Industries 4070806 100-01191_000Auger MotorWhen feeding pellets, you may hear the intermittent buzz of this motor r

Página 34

4 Safety Precautions© Travis Industries 4070806 100-01191_000• Do not operate theheater if you smellsmoke coming fromthe heater. Turn theMODE switch

Página 35 - Maintenance 35

40 Safety Label© Travis Industries 4070806 100-01191_000

Página 36

Limited 7 Year Warranty 41© Travis Industries 4070806 100-01191_000To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed war

Página 37 - Maintenance 37

42 Index© Travis Industries 4070806 100-01191_000"AUGER ON" Light...25"FAULT" Light...

Página 38

Safety Precautions 5© Travis Industries 4070806 100-01191_000• The heater will not operateduring a power outage. Ifa power outage doesoccur, check t

Página 39 - Normal Operating Sounds 39

6 Specifications© Travis Industries 4070806 100-01191_000Heating SpecificationsApproximate Maximum Heating Capacity (in square feet)* ...

Página 40 - Safety Label

Installation (For Qualified Installers Only) 7© Travis Industries 4070806 100-01191_000Before You BeginREAD THIS ENTIRE MANUAL BEFORE YOU INSTALL AND

Página 41 - Limited 7 Year Warranty 41

8 Installation (For Qualified Installers Only)© Travis Industries 4070806 100-01191_000Clearances - Straight Installation7” Minimum6” Minimum3” Minim

Página 42 - 42 Index

Installation (For Qualified Installers Only) 9© Travis Industries 4070806 100-01191_000Venting the Pellet Stove• PELLET VENT MUST MAINTAIN A MINIMUM

Comentários a estes Manuais

Sem comentários