ArborPellet Stove• Horizontal Or Vertical Vent• Freestanding Stove• Mobile Home Approved• Class A Chimney Retrofit• Hearth Stove into ExistingMasonry
10 Installation (For Qualified Installers Only)© Travis Industries 4070806 100-01191_000Pellet Vent Type• Must be 4" diameter Type "L"
Installation (For Qualified Installers Only) 11© Travis Industries 4070806 100-01191_000Mobile Home Requirements• Outside air is required (used forco
12 Installation (For Qualified Installers Only)© Travis Industries 4070806 100-01191_000Alcove Installation RequirementsWhen the pellet stove is plac
Installation (For Qualified Installers Only) 13© Travis Industries 4070806 100-01191_000Thermostat Installation! Do not connect 120 VAC to the thermo
14 Installation (For Qualified Installers Only)© Travis Industries 4070806 100-01191_000Installation Example: Direct "Through-the-wall" Ins
Installation (For Qualified Installers Only) 15© Travis Industries 4070806 100-01191_000Installation Example: Interior Vertical InstallationFloor Pr
16 Installation (For Qualified Installers Only)© Travis Industries 4070806 100-01191_000Installation Example: Class A Chimney RetrofitFloor Protectio
Installation (For Qualified Installers Only) 17© Travis Industries 4070806 100-01191_000Installation Example: Masonry Fireplace Hearth Stove“L” Vent
18 Installation (For Qualified Installers Only)© Travis Industries 4070806 100-01191_000Installation Example: Zero-Clearance (Metal) Fireplace Hearth
Installation (For Qualified Installers Only) 19© Travis Industries 4070806 100-01191_000Installation Example: Freestanding Masonry Chimney6” Min.Allo
2 Introduction© Travis Industries 4070806 100-01191_000IntroductionWe welcome you as a new owner of an Arbor pellet heater. In purchasing an Arbor yo
20 Operation© Travis Industries 4070806 100-01191_000Safety NoticeRead this entire manual (especially the "Safety Precautions" on pages 4 an
Operation 21© Travis Industries 4070806 100-01191_000Loading PelletsLift the hopper lid to its vertical position. Pour pellets into the hopper until
22 Operation© Travis Industries 4070806 100-01191_000Manual ModeManual mode requires the user to turn theheater on and off manually.To StartPress the
Operation 23© Travis Industries 4070806 100-01191_000Auto ModeAuto mode allows you to use a thermostat to control room temperature. The stove automat
24 Operation© Travis Industries 4070806 100-01191_000Restrictor AdjustmentThe restrictor “fine tunes” your appliance, adjusting the amount of air flow
Operation 25© Travis Industries 4070806 100-01191_000Start-Up SequenceThis stove utilizes a start-up sequence whenever the mode switch is changed or t
26 Operation© Travis Industries 4070806 100-01191_000Using a Pellet/Corn Mix with This HeaterThis heater may burn a mixture of corn and wood pellets u
Maintenance 27© Travis Industries 4070806 100-01191_000Daily Maintenance (whenever using the stove)Inspect the BurnWhen burning on high, theflames sho
28 Maintenance© Travis Industries 4070806 100-01191_000Daily Maintenance (whenever using the stove) - ContinuedCheck Firepot forClinkersIf the flames
Maintenance 29© Travis Industries 4070806 100-01191_000Daily Maintenance (whenever using the stove) - ContinuedDoor OpeningWARNING : Make sure the h
Table of Contents 3© Travis Industries 4070806 100-01191_000IntroductionIntroduction...2Important I
30 Maintenance© Travis Industries 4070806 100-01191_000Bi-Weekly Maintenance (or every 10 bags of pellets)Flyash RemovalThis heater was designed to al
Maintenance 31© Travis Industries 4070806 100-01191_000Bi-Weekly Maintenance (or every 10 bags of pellets) - continuedClean the BafflesWARNING : Ma
32 Maintenance© Travis Industries 4070806 100-01191_000Bi-Weekly Maintenance (or every 10 bags of pellets) - continuedSweep Ash Into AshpanWARNING :
Maintenance 33© Travis Industries 4070806 100-01191_000Bi-Weekly Maintenance (or every 10 bags of pellets) - continuedCheck Ashpan, Dispose if necessa
34 Maintenance© Travis Industries 4070806 100-01191_000Yearly Maintenance (or every two tons)The following section details extensive maintenance proce
Maintenance 35© Travis Industries 4070806 100-01191_000Yearly Maintenance (or every two tons) - continuedRemove the button plugs at the top of the fir
36 Maintenance© Travis Industries 4070806 100-01191_000Yearly Maintenance (or every two tons) - continuedClean the Exhaust BlowerThe exhaust blower co
Maintenance 37© Travis Industries 4070806 100-01191_000Yearly Maintenance (or every two tons) - continuedClean the Convection BlowerRemove all dust an
38 Maintenance© Travis Industries 4070806 100-01191_000Replacement PartsDoor Replacement Parts59810437261ID # Description Qty Part # ID # Description
Normal Operating Sounds 39© Travis Industries 4070806 100-01191_000Auger MotorWhen feeding pellets, you may hear the intermittent buzz of this motor r
4 Safety Precautions© Travis Industries 4070806 100-01191_000• Do not operate theheater if you smellsmoke coming fromthe heater. Turn theMODE switch
40 Safety Label© Travis Industries 4070806 100-01191_000
Limited 7 Year Warranty 41© Travis Industries 4070806 100-01191_000To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed war
42 Index© Travis Industries 4070806 100-01191_000"AUGER ON" Light...25"FAULT" Light...
Safety Precautions 5© Travis Industries 4070806 100-01191_000• The heater will not operateduring a power outage. Ifa power outage doesoccur, check t
6 Specifications© Travis Industries 4070806 100-01191_000Heating SpecificationsApproximate Maximum Heating Capacity (in square feet)* ...
Installation (For Qualified Installers Only) 7© Travis Industries 4070806 100-01191_000Before You BeginREAD THIS ENTIRE MANUAL BEFORE YOU INSTALL AND
8 Installation (For Qualified Installers Only)© Travis Industries 4070806 100-01191_000Clearances - Straight Installation7” Minimum6” Minimum3” Minim
Installation (For Qualified Installers Only) 9© Travis Industries 4070806 100-01191_000Venting the Pellet Stove• PELLET VENT MUST MAINTAIN A MINIMUM