Avalon-stoves Avalon Pellet Stove Astoria PS Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Ferramentas Avalon-stoves Avalon Pellet Stove Astoria PS. Avalon Stoves Avalon Pellet Stove Astoria PS User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 42
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Astoria
Pellet Stove
Horizontal Or Vertical Vent
Freestanding Stove
Mobile Home Approved
Class A Chimney Retrofit
Hearth Stove into Existing
Masonry Chimney , Masonry
Fireplace, or Z.C. Fireplace
-- Please read this entire manual before
installation and use of this pellet fuel-
burning room heater. Failure to follow
these instructions could result in
property damage bodily injury or even
death.
-- Contact local building or fire officials
about restrictions and installation
inspection requirements in your area.
Tested and Listed by
OMNI-Test Laboratories, Inc.
Beaverton, Oregon
Report # 028–S–42-2
ASTME-1509 1995, ULCC 1482
Owner's Manual
Installer: After installation give this manual to the home-owner
and explain operation of this heater.
Copyright 2007, T.I. $10.00 100-01154 4051227
4800 Harbour Pointe Blvd. SW
Mukilteo, WA 98275
Vista de página 0
1 2 3 4 5 6 ... 41 42

Resumo do Conteúdo

Página 1 - Pellet Stove

AstoriaPellet Stove• Horizontal Or Vertical Vent• Freestanding Stove• Mobile Home Approved• Class A Chimney Retrofit• Hearth Stove into ExistingMason

Página 2 - Introduction

10 InstallationTravis Industries 4050225 100-01154Pellet Vent Type• Must be 4" diameter Type "L"(except for masonry fireplace installat

Página 3 - Table of Contents 3

Installation 11Travis Industries 4050225 100-01154Mobile Home Requirements• Outside air is required (used forcombustion) - see the directionsbelow.• T

Página 4 - Safety Precautions

12 InstallationTravis Industries 4050225 100-01154Alcove Installation RequirementsWhen the pellet stove is placed in a location where the ceiling heig

Página 5 - Safety Precautions 5

Installation 13Travis Industries 4050225 100-01154Installation Example: Direct "Through-the-wall" Installation3” Minimum9” MinimumFloor Prot

Página 6 - Specifications

14 InstallationTravis Industries 4050225 100-01154Installation Example: Interior Vertical InstallationType "L" Vent6” Minimum3” MinimumFloo

Página 7 - Installation 7

Installation 15Travis Industries 4050225 100-01154Installation Example: Class A Chimney RetrofitType "L" Vent6” Minimum3” MinimumFloor Prote

Página 8

16 InstallationTravis Industries 4050225 100-01154Installation Example: Masonry Fireplace Hearth StoveOutside air may be drawn from the ash cleanout.6

Página 9 - Installation 9

Installation 17Travis Industries 4050225 100-01154Installation Example: Zero-Clearance (Metal) Fireplace Hearth Stove“L” Vent Flex Section6” Min.“L”

Página 10 - Installation

18 InstallationTravis Industries 4050225 100-01154Installation Example: Freestanding Masonry Chimney“L” Vent Sections6” Min.“L” VentStorm CollarVertic

Página 11 - Installation 11

Operation 19Travis Industries 4050225 100-01154Safety NoticeRead this entire manual (especially the "Safety Precautions" on pages 4 and 5)be

Página 12

2 IntroductionTravis Industries Heritage PS 270603IntroductionWe welcome you as a new owner of an Astoria pellet heater. In purchasing an Astoria you

Página 13 - Installation 13

20 OperationTravis Industries 4050225 100-01154Loading PelletsLift the hopper lid to its vertical position. Pour pellets into the hopper until full.

Página 14

Operation 21Travis Industries 4050225 100-01154Manual ModeManual mode requires the user to turn theheater on and off manually.To StartPress the "

Página 15 - Installation 15

22 OperationTravis Industries 4050225 100-01154Auto ModeAuto mode allows you to use a thermostat to control room temperature. The stove automatically

Página 16

Operation 23Travis Industries 4050225 100-01154Restrictor AdjustmentThe exhaust restrictor “fine tunes” your appliance, adjusting the amount of air fl

Página 17 - Installation 17

24 OperationTravis Industries 4050225 100-01154Start-Up SequenceThis stove utilizes a start-up sequence whenever the mode switch is changed or the hea

Página 18

Maintenance 25Travis Industries 4050225 100-01154Daily Maintenance (whenever using the stove)Inspect the BurnWhen burning on high, theflames should be

Página 19 - Operation 19

26 MaintenanceTravis Industries 4050225 100-01154Daily Maintenance (whenever using the stove) - ContinuedCheck Firepot forClinkersIf the flames seem t

Página 20 - Operation

Maintenance 27Travis Industries 4050225 100-01154Door OpeningWARNING : Make sure the heater has fully cooled (approximately 25 minutes) before open

Página 21 - Operation 21

28 MaintenanceTravis Industries 4050225 100-01154Bi-Weekly Maintenance (or every 10 bags of pellets)Clean the Heat Exchange TubesHeat Exchanger Cleani

Página 22

Maintenance 29Travis Industries 4050225 100-01154Bi-Weekly Maintenance (or every 10 bags of pellets) - ContinuedClean the BafflesUse both hands to lif

Página 23 - Operation 23

Table of Contents 3Travis Industries 4050225 100-01154IntroductionIntroduction...2Important Informa

Página 24

30 MaintenanceTravis Industries 4050225 100-01154Sweep Ash Into AshpanHINT: The more often you clean out the flyash, the more efficient your heater wi

Página 25 - Maintenance 25

Maintenance 31Travis Industries 4050225 100-01154Bi-Weekly Maintenance (or every 10 bags of pellets) - ContinuedCheck Ashpan, Dispose if necessaryNOTE

Página 26 - Maintenance

32 MaintenanceTravis Industries 4050225 100-01154Yearly Maintenance (or every two tons)WARNING: Disconnect the power cord prior to conducting service.

Página 27 - Maintenance 27

Maintenance 33Travis Industries 4050225 100-01154Yearly Maintenance (or every two tons) - ContinuedClean the Exhaust Blower (make sure the stove is co

Página 28

34 MaintenanceTravis Industries 4050225 100-01154Yearly Maintenance (or every two tons) - ContinuedDoor Seal! Air leaks into the firebox will decrease

Página 29 - Maintenance 29

Maintenance 35Travis Industries 4050225 100-01154Adjusting the Door Hinge and Latch• The door hinge and door latches may be adjusted to pull the door

Página 30

36 MaintenanceTravis Industries 4050225 100-01154Check for Air Leaks Around the Door, Glass, and Ashpan! Air leaks into the firebox will decrease the

Página 31 - Maintenance 31

Normal Operating Sounds 37Travis Industries 4050225 100-01154Auger MotorWhen feeding pellets, you may hear the intermittent buzz of this motor running

Página 32

38 Safety LabelTravis Industries 4050225 100-01154WARNING - DO NOT REMOVE OR COVER THIS LABELListed PelletizedSolid Fuel Burning ApplianceAlso for Use

Página 33 - Maintenance 33

Limited 7 Year Warranty 39Travis Industries 4050225 100-01154To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty

Página 34

4 Safety PrecautionsTravis Industries 4050225 100-01154• Do not operate theheater if you smellsmoke coming fromthe heater. Turn theMODE switch to&qu

Página 35 - Maintenance 35

40 Optional EquipmentTravis Industries 4050225 100-01154Thermostat (Part # 99300650)! Do not connect 120 VACto the thermostat circuit ofthis heater (d

Página 36

Optional Equipment 41Travis Industries 4050225 100-01154 Remote ThermostatFollow the instructions included with the remote thermostat for installation

Página 37 - Normal Operating Sounds 37

42 IndexTravis Industries 4050225 100-01154Adjusting the Fan Speed...23Air Leaks...

Página 38 - Safety Label

Safety Precautions 5Travis Industries 4050225 100-01154• The heater will not operateduring a power outage. Ifa power outage doesoccur, check the hea

Página 39 - Limited 7 Year Warranty 39

6 SpecificationsTravis Industries 4050225 100-01154Heating Specifications:Approximate Maximum Heating Capacity (in square feet)*...

Página 40 - Optional Equipment

Installation 7Travis Industries 4050225 100-01154Before You BeginREAD THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER.FAILURE TO FOLLOW THE

Página 41 - Optional Equipment 41

8 InstallationTravis Industries 4050225 100-01154Clearances - Straight Installation6” Minimum3” Minimum9” Minimum3” MinimumThrough the Wall Installati

Página 42 - 42 Index

Installation 9Travis Industries 4050225 100-01154Venting the Pellet Stove• PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE TO ANYCOMBUSTIBLE (IN

Comentários a estes Manuais